|
|
40ft PVC Central Vac Pipe (ten 4-ft) (Ground Ship)
Great for medium central vacuum jobs such as
repairs, relocating a valve, adding a valve, exhausting, etc. Be sure to
get extra PVC couplings (below) to fit it all together. This vacuum tubing
is 2-inch outer diameter. Manufactured to ASTM standard F2158.
SHIPPED REGULAR GROUND ONLY
|
|
|
|
4ft PVC Central Vacuum Pipe (two 2-foot tubes)
Comes in two 2-foot sections. If putting two
pieces together use a coupling. Manufactured to ASTM standard F2158.
|
|
|
4ft PVC Central Vacuum Pipe
Each pipe is 4 foot
long---select the number of sticks you wish to purchase
|
|
|
|
45 Spigot PVC Vacuum Connector
Spigot fittings are made to fit directly into
other fittings. This will prove helpful in tight spots!
|
|
|
|
45 EL
We suggest using 45's, even two of them when
possible, to use less 90's. When the pipe line needs to run up or down,
angle a 90 at 45-degrees into a 45 fitting
|
|
|
|
90 Spigot PVC Vacuum Connector
Spigot fittings are made to fit directly into
other fittings. This will prove helpful in tight spots!
|
|
|
|
90 Sweep PVC Vacuum Connector
Probably the most used item. Remember this can not be used behind the
inlet bracket--use the short 90 instead
|
|
|
|
90 Sweep Tee PVC Vacuum 3-way Connector
For connecting a branch to the main line. Be
sure the airflow is adequate. Do not install the tee backwards!
|
|
|
|
45 Wye PVC Vacuum 3-way Connector
For connecting a branch to the main line. Be
sure the airflow is adequate. Do not install the wye backwards!
|
|
|
|
short 90
Use this fitting at the mounting plates only.
Since this is the sharpest turn in the system, potential clogging will
occur with easy access - right at the inlet valve!
|
|
|
|
Stop Coupler
For connecting two pieces of pipe together. If
you need a case, enter 175 for the quantity.
|
|
|
|
Pipe hanger
Used to hold 2" OD Central Vacuum Pipe in
position
|
|
|
|
J shaped Pipe Hanger
Used to hang 2" OD Central Vacuum Pipe at
a distance of a foot or less. Comes with a nail. Make of sturdy PVC. The
pipe snaps into the J and looks real clean
|
|
|
Supervalve Mounting Bracket
Includes 110v wire connector
No inlet included
|
|
|
|
3-in-1 Mounting Bracket PVC
Most popular bracket for all Basic Inlet Valve
Covers. For new construction nail it to a stud. For existing home
installation cut the stud side off and set it in a 2x4" drywall
cutout. When piping, connect a fitting such as a tight 90 or coupling to
the flange. Finish it with a basic inlet valve cover.
|
|
|
|
Inlet Valve Extension
Use as many of these as needed when the wall,
for any reason, is too thick causing the mounting plate and finished plate
to not meet. Longer screws will be needed as well. It adds 3/4 of an inch
to the cover plate. If that is too much you can cut to size.
DIAMETERS: Large end inner is 1 5/8", outer is 1 7/8". Small end
inner is 1 1/2", outer is 1 5/8".
|
|
|
|
Exhaust Vent Door for Central Vacuum Pipe
Installed on the outside of the home to exhaust
the power unit. This is not needed with M.D.'s bag type units. Fits
2" OD (Vacuum PVC Pipe). Overall size is 3-5/8"w X 4-5/8"h
|
|
|
|
Muffler for vacuum fits 2-inch OD exhaust ports
Is your power unit too loud? Decrease that irritating sound by inserting this muffler into
any central vacuum that has 2" OD diameter exhaust ports. One
muffler per exhaust port on the vacuum itself. Use a 90 Spigot Sweep to install it vertically if
desired.
|
|
|
|
Inlet Blank Cover Plate,
(3 in a pack)
Three cover plates come in one package. Use the
cover plate to cover up a old vacuum hole in the sheet rock or to gain
access into a wall. The dimensions are 4-3/4" tall by three inches wide.
Screw holes on center are 3-7/8" apart from each other at 12 and 6
o'clock.
|
|
|
PVC Wire Ties 100 count
The low voltage wire that is run along the pipe should be anchored to the pipe every 4 feet and at every joint with these wire ties.
|
|

Select to enlarge
|
Install Kit with 1 Electric Inlet
Includes the following items pictured. Add pipe
(24ft recommended). Buy regular PVC cement from a local store. Includes
inlet valve and backing plate. The included 25ft of wire
is low voltage and runs from the faceplate to the vacuum canister to turn
it on. In addition, Romex (110 volt) wire from a local store is need for
the 110 volts. The faceplates' 110 volt wires connect to the romex you
stub out from the backing plate box during rough-in
|
|

Select to enlarge
|
Install Kit with 1
non-Electric Inlet
Includes the following items pictured. Add pipe
(24ft recommended). Buy regular PVC cement from a local store. Includes a
square door inlet valve and backing plate. The included 25ft of wire
is low voltage and runs from the faceplate to the vacuum canister to turn
it on. The inlet is not set-up for electricity. This is a non-electric kit
|
|